20% OFF shipping at www.carladuclos.com on orders over $79 + up to 10% OFF products
www.carladuclos.com
home > Hioki CT6863 200A AC/DC Current Sensor > Hioki CT6863 200A AC/DC Current Sensor
download picture
Hioki CT6863 200A AC/DC Current SensorHioki CT6863 200A AC DC Current Sensor Key Features At A Glance AC DC current sensing across the series with 50 A, 200 A, and 500 A rms rated models Bandwidth ranging from DC to 1 MHz at the top of the series down to DC to 100 kHz Basic accuracy of 0. 05% rdg. 0. 01% f. s. 0. 2 deg (DC and 16 Hz f 400 Hz) Voltage output of 2 V at rated current with 50 output resistance Maximum accuracy of 0. 16% when used with the POWER ANALYZER 3390 Maximum rated
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Hioki CT6863 200A AC/DC Current Sensor

Key Features At A Glance

  • AC/DC current sensing across the series with 50 A, 200 A, and 500 A rms rated models
  • Bandwidth ranging from DC to 1 MHz at the top of the series down to DC to 100 kHz
  • Basic accuracy of ±0.05% rdg. ±0.01% f.s. ±0.2 deg (DC and 16 Hz ≤ f ≤ 400 Hz)
  • Voltage output of 2 V at rated current with 50 Ω output resistance
  • Maximum accuracy of ±0.16% when used with the POWER ANALYZER 3390
  • Maximum rated voltage to earth of AC/DC 1000 V (50/60 Hz), measurement category III (CAT III 1000 V)
  • Compatible with the 3193 (with 9602), 3194 (with 9602), 3390, and PW6001 power meters
  • 3 m cord length; supplied with an instruction manual and six mark bands

The HIOKI CT6862, CT6863, and 9709 are wide-bandwidth, high-precision AC/DC current sensors that achieve high-accuracy measurement of both small- and large-current signals. Each model provides an isolated current input that converts the measured conductor current into a proportional voltage output — 2 V at the rated current — with a 50 Ω output resistance, allowing the measured signal to be carried to a connected power meter without the long signal-cable effects of a direct connection.

Across the series these sensors support a wide variety of applications in the fields of electric and hybrid electric vehicles, inverters and other devices, and alternative energy sources such as solar power and fuel cells, as well as home electronic appliances and system equipment. They are also suited to comprehensive evaluation of wide-bandwidth, high-precision inverter motors, and to measurements including battery charge and discharge and inverter secondary-circuit measurement.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, so the instruments you order are units we keep on hand rather than sourced on demand.

Compare Other Models in This Series

The HIOKI AC/DC current sensor series comprises three models — the CT6862, CT6863, and 9709 — that share a common high-precision, wide-bandwidth measurement approach but differ in rated current and frequency characteristics. All three deliver a 2 V output at rated current, a 50 Ω output resistance, and the same basic accuracy specification, and all carry a maximum rated voltage to earth of AC/DC 1000 V at measurement category III.

Each model is also offered in a standard version and a -05 version with a 12-pin terminal, giving the CT6862 / CT6862-05, CT6863 / CT6863-05, and 9709 / 9709-05 order codes. The choice between models is driven primarily by the current level and bandwidth a given measurement requires.

Each model below links to its own dedicated product page with new-condition pricing. Select the model that matches your required rated current and bandwidth, then choose the new unit on that model's page.

The models are distinguished by rated current and bandwidth: the CT6862 is rated at 50 A AC/DC with a bandwidth of DC to 1 MHz, the CT6863 at 200 A AC/DC with DC to 500 kHz, and the 9709 at 500 A AC/DC with DC to 100 kHz. Higher rated current in the series corresponds to a lower upper bandwidth limit, so the model selection balances the current to be measured against the frequency content of interest.

Mechanical and conductor-handling differences accompany the electrical tiers, including measurable conductor diameter (26 mm or less, and 36 mm or less depending on model) and physical size and mass. See the comparison table that follows for the per-model rated current, bandwidth, output, dimensions, and accuracy-guarantee period.

Model Rated Current Bandwidth Output Voltage
CT6863 200 A AC/DC DC to 500 kHz 2 V/200 A
CT6862 50 A AC/DC DC to 1 MHz 2 V/50 A
CT6862 50 A AC/DC DC to 1 MHz 2 V/50 A
9709 500 A AC/DC DC to 100 kHz 2 V/500 A

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Instruction manual ×1
  • Mark bands ×6

Product Core & Specifications

Specification Value
Current Sensing
Rated current 200 A AC/DC
Frequency characteristics DC to 500 kHz
Output voltage 2 V/200 A
Output resistance 50 Ω
Measurable conductor diameter 26 mm (1.02 in.) or less
Basic Accuracy
DC, 16 Hz ≤ f ≤ 400 Hz (0°C to 40°C, 80% RH or less) ±0.05% rdg. ±0.01% f.s. ±0.2 deg
DC, 45 Hz ≤ f ≤ 66 Hz (18°C to 28°C, up to 80% RH) ±0.05% rdg. ±0.01% f.s. ±0.2 deg
Period of accuracy guaranteed Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year
General
Max. rated voltage to earth AC/DC 1000 V (50/60 Hz) (measurement category III)
Cord length 3 m (9.84 ft)
Operating temperature and humidity range -30°C to 85°C, 80% RH or less (with no condensation)
Dimensions 70W (2.76 in.) × 100H (3.94 in.) × 53D (2.09 in.) mm
Mass 340 g (12.0 oz)
Supplied accessories Instruction manual ×1, Mark bands ×6
Important: Maximum rated voltage to earth: AC/DC 1000 V (50/60 Hz), measurement category III (CAT III 1000 V).
Important: Extension Cable 9706 cannot be used in combination with the CT6862/63 or 9277 to 9279.
Important: Both the 9318 and 9705 are required in order to connect to the F/V Unit 8940.
Important: Conversion Cable CT9900 (current sensor connector 10 pins to 12 pins) is required for connecting to the PW6001.
Recommended pairing: use these sensors with the POWER ANALYZER 3390 to reach the maximum ±0.16% accuracy stated for the series.

About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Hioki CT6863 200A AC/DC Current Sensor

Item no : 13116463045
sold recently : Login >>
US$ 874.00
Pay in 4 interest-free payments of $218.50 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 874.00

1-11

US$ 786.60

12-35

US$ 611.80

36-59

US$ 524.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches