Hioki CT6904 500 A AC/DC Current SensorHioki CT6904 500 A AC DC Current Sensor Key Features At A Glance 500 A (rms) AC DC rated current measurement for large current applications DC to 4 MHz (3 dB typical) measurement frequency range. 0. 02% rdg. (0. 007% f. s.) basic accuracy with 10 ppm typical linearity at 23C CMRR of 120 dB or greater at 100 kHz (140 dB or greater at 50 60 Hz) for high noise immunity Zero flux (fluxgate detection) method with newly developed opposed split coil
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Hioki CT6904 500 A AC/DC Current Sensor

Key Features At A Glance

  • 500 A (rms) AC/DC rated current measurement for large-current applications
  • DC to 4 MHz (±3 dB typical) measurement frequency range.
  • ±0.02% rdg. (±0.007% f.s.) basic accuracy with ±10 ppm typical linearity at 23°C
  • CMRR of 120 dB or greater at 100 kHz (140 dB or greater at 50/60 Hz) for high noise immunity
  • Zero-flux (fluxgate detection) method with newly developed opposed split coil technology
  • Maximum rated voltage to ground 1000 V CAT III; measurable conductor diameter up to φ32 mm
  • Powered through dedicated ME15W interface from PW6001, PW3390, or CT9555
  • 4 mV/A output; approx. 1.0 kg with ~3 m output cable (10 m available made-to-order)

The CT6904 is an ultra-high-performance AC/DC current sensor from HIOKI built for the measurement of large currents up to 500 A (rms). It applies the zero-flux (fluxgate detection) measurement method, in which high-frequency current is detected with windings (CT method) and direct-to-low-frequency current is detected with fluxgates. A newly developed opposed split coil technology is used in the winding areas, achieving a wide measurement range from DC to 4 MHz — a range described as 40× that of conventional models — while a uniquely shaped solid aluminum shield surrounds the coil to eliminate the influence of surrounding voltage on the measurement.

The sensor targets the power electronics, natural energy, and automotive industries, where high inverter efficiency and improved power-saving performance are in demand. Listed applications include high-precision and efficiency testing of SiC/GaN inverters — where its flat frequency characteristics allow accurate measurement of both fundamental-wave current and switching-frequency current during PWM output — and reactor and transformer loss analysis for power converters, where its noise resistance lets switching current that had been obscured by noise be measured accurately. In these roles it is used together with a power analyzer to measure inverter input/output power and efficiency.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois, so the current sensors and companion instruments you order are on hand rather than sourced on demand.

Accessories Supplied

  • Instruction manual x 1
  • Carrying case x 1
  • Color labels (for channel identification) x 1

Product Core & Specifications

Specification Value
Input, Output & Measurement (Basic Specifications)
Rated primary current 500 A AC/DC
Diameter of measurable conductors φ 32 mm (1.26 in) or less
Maximum input current Within derating shown in the derating figure. However, up to ±1000 A peak is allowable if within 20 ms (design value). When measuring current in the vicinity of derating, use a cooling time that is 10x or more greater than current input time.
Output voltage 4 mV/A
Maximum rated voltage to ground 1000 V CAT III; Expected transient overvoltage: 8000 V
Linearity ±10 ppm Typical (23°C (73°F))
Offset voltage ±10 ppm Typical (23°C (73°F), no input)
Accuracy guarantee conditions Guaranteed accuracy period: 1 year; after adjustment by Hioki: 1 year. Temperature and humidity for guaranteed accuracy: 23°C ±5°C (73°F ±9°F), 80% RH or less. Warm-up time: 30 min. or more. Input waveform: sine wave. Connection: measuring instrument with an input resistance of 0.9 MΩ to 1.1 MΩ. Terminal-to-ground voltage: 0 V, no external magnetic field, conductor center position.
Accuracy Specifications (Amplitude / Phase)
DC Amplitude: ±0.025% rdg. ±0.007% f.s.; Phase: —
DC < f < 16 Hz Amplitude: ±0.2% rdg. ±0.02% f.s.; Phase: ±0.1°
16 Hz ≤ f < 45 Hz Amplitude: ±0.1% rdg. ±0.02% f.s.; Phase: ±0.1°
45 Hz ≤ f ≤ 65 Hz Amplitude: ±0.02% rdg. ±0.007% f.s.; Phase: ±0.08°
65 Hz < f ≤ 850 Hz Amplitude: ±0.05% rdg. ±0.007% f.s.; Phase: ±0.12°
850 Hz < f ≤ 1 kHz Amplitude: ±0.1% rdg. ±0.01% f.s.; Phase: ±0.4°
1 kHz < f ≤ 5 kHz Amplitude: ±0.4% rdg. ±0.02% f.s.; Phase: ±0.4°
5 kHz < f ≤ 10 kHz Amplitude: ±0.4% rdg. ±0.02% f.s.; Phase: ±(0.08×f)°
10 kHz < f ≤ 50 kHz Amplitude: ±1% rdg. ±0.02% f.s.; Phase: ±(0.08×f)°
50 kHz < f ≤ 100 kHz Amplitude: ±1% rdg. ±0.05% f.s.; Phase: ±(0.08×f)°
100 kHz < f ≤ 300 kHz Amplitude: ±2% rdg. ±0.05% f.s.; Phase: ±(0.08×f)°
300 kHz < f ≤ 1 MHz Amplitude: ±5% rdg. ±0.05% f.s.; Phase: ±(0.08×f)°
Frequency range 4 MHz (±3 dB Typical)
Effects of temperature Within -10°C to 18°C (14°F to 64°F) or 28°C to 50°C (82°F to 122°F): Amplitude sensitivity ±0.005% rdg./°C; Offset voltage ±0.005% f.s./°C; Phase ±0.01°/°C
Common-mode voltage rejection ratio (CMRR) 140 dB or greater (50 Hz/60 Hz), 120 dB or greater (100 kHz) (Effect on output voltage/common-mode voltage)
Effect of conductor position ±0.01% rdg. or less (100 A input, 50 Hz/60 Hz), when using wire with 10 mm (0.39 in) outer diameter
Combined Accuracy (PW6001 accuracy + CT6904 accuracy, f.s. = PW6001 Range)
DC Current: ±0.045% rdg. ±0.037% f.s.; Power: ±0.045% rdg. ±0.057% f.s.
45 Hz ≤ f ≤ 65 Hz Current: ±0.04% rdg. ±0.027% f.s.; Power: ±0.04% rdg. ±0.037% f.s.
Combined accuracy notes For 10 A Range and 20 A Range, apply ±0.12% f.s. (f.s. = PW6001 Range). For other bandwidths, add PW6001 accuracy + CT6904 accuracy (consider sensor rating when calculating f.s. error). With CT9555: sensor accuracy x 1.5 (when the output coaxial cable is no longer than 1.6 m (5.25 ft)); for a 10 m output cable (made to order), frequency range 1 MHz (±3 dB Typical).
General Specifications
Operating environment Indoors, Pollution Degree 2, altitude up to 2000 m (6562.20 ft)
Operating temperature and humidity range -10°C to 50°C (14°F to 122°F), and 80% RH or less (no condensation)
Storage temperature and humidity range -20°C to 60°C (-4°F to 140°F), and 80% RH or less (no condensation)
Dielectric withstand voltage 7.4 kV AC (sensed current of 1 mA), 50 Hz/60 Hz: 1 min (Distance between feed-through window and cable output terminal)
Power supply Power supplied from PW6001, PW3390, and CT9555
Max. power consumption 7 VA (500 A/55 Hz measurement, with a power supply of ±12 V)
Interface Dedicated interface (ME15W)
Dimensions Approx. 139 mm (5.47 in) W × 120 mm (4.72 in) H × 52 mm (2.05 in) D (excluding protrusions and cables)
Output cable length Approx. 3 m (9.84 ft) (including relay box). For a 10 m (32.81 ft) output cable (made to order): approx. 10 m (32.81 ft) (including relay box).
Bracket hole diameter φ 5.2 mm (0.20 in) (M5 screws, Recommended tightening torque: 1.5 N·m to 2.0 N·m)
Mass Approx. 1.0 kg (35.3 oz). For a 10 m output cable (made to order): approx. 1.3 kg (45.9 oz).
Product warranty period 3 years
Important: Maximum rated voltage to ground: 1000 V CAT III (expected transient overvoltage 8000 V).
Important: Maximum input current is limited by the derating curve. Up to ±1000 A peak is allowable if within 20 ms (design value). When measuring current in the vicinity of derating, use a cooling time that is 10x or more greater than the current input time.
Important: The CT6904 is powered from and connects to a compatible Hioki host instrument (POWER ANALYZER PW6001, POWER ANALYZER PW3390, or SENSOR UNIT CT9555) via the dedicated ME15W interface; a compatible host instrument is required to operate the sensor and is not part of the sensor's standard delivery.
Important: A 10 m (32.81 ft) output cable is available as a made-to-order option; with it, add an amplitude accuracy of ±(0.015×f)% rdg. for 50 kHz < f ≤ 1 MHz and the frequency range becomes 2 MHz (±3 dB Typical).
Recommended pairing: use the CT6904 with the HIOKI POWER ANALYZER PW6001 (also connectable to the PW3390 and SENSOR UNIT CT9555) to enable the phase-compensated, combined-accuracy measurements named in the specifications.

About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Hioki CT6904 500 A AC/DC Current Sensor

Item no : 3937383757
sold recently : Login >>
US$ 2625.00
Pay in 4 interest-free payments of $656.25 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 23 - Jun 28

Enjoy 20% off shipping

US$ 2625.00

1-11

US$ 2362.50

12-35

US$ 1837.50

36-59

US$ 1575.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches