HT Italia HT63 CAT IV 60000-Count TRMS MultimeterHT Italia HT63 CAT IV 60000 Count TRMS Multimeter Key Features At A Glance CAT IV 600V CAT III 1000V measurement category with double insulation per IEC EN61010 1 60000 count TRMS display with dual 3 digit (6000) and 4 digit (60000) resolution, bargraph, and backlight TRMS measurement of AC, DC, and AC+DC voltage and current Low impedance LoZ mode (~3k input) for AC DC voltage measurement AC DC current measurement with transducer clamps up to 3000A
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

HT Italia HT63 CAT IV 60000-Count TRMS Multimeter

Key Features At A Glance

  • CAT IV 600V / CAT III 1000V measurement category with double insulation per IEC/EN61010-1
  • 60000-count TRMS display with dual 3½-digit (6000) and 4½-digit (60000) resolution, bargraph, and backlight
  • TRMS measurement of AC, DC, and AC+DC voltage and current
  • Low-impedance LoZ mode (~3kΩ input) for AC/DC voltage measurement
  • AC/DC current measurement with transducer clamps up to 3000A
  • Type K thermocouple temperature measurement from -40°C to 760°C
  • Capacitance to 6mF, frequency to 10MHz, resistance to 60MΩ
  • DC 4-20mA% loop readings plus PEAK, MAX/MIN, REL, and Data/Auto HOLD functions

The HT63 is a CAT IV 60000-count true-RMS (TRMS) digital multimeter manufactured by HT Instruments (HT Italia SRL). It pairs a dual-resolution LCD — 3½-digit at 6000 counts and 4½-digit at 60000 counts — with a bargraph, backlight, automatic polarity indication, and an "OL" over-range indication, and applies TRMS conversion across its AC measurement functions.

A digital multimeter is the most universal instrument on an electrical or electronics bench, consolidating voltage, current, resistance, and a range of derived measurements into a single handheld unit. A true-RMS meter measures the actual heating value of an AC signal, which keeps readings accurate on the distorted, non-sinusoidal waveforms common in modern electrical systems.

ValueTronics stocks and holds its own inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.

Product Core & Specifications

Specification Value
General Accuracy Conditions
Accuracy formula [reading + (num dgt × resolution)] at ta 18°C–28°C, <75% RH
HIRES feature Accuracy specified with HIRES not active; with HIRES active, multiply ×10 the dgts of the accuracy
DC Voltage (Input impedance >10 MΩ; Overload protection 1000 V DC/AC rms)
600.0 mV Resolution 0.1 mV; Accuracy (0.9%rdg + 5dgt)
6.000 V Resolution 0.001 V; Accuracy (0.9%rdg + 5dgt)
60.00 V Resolution 0.01 V; Accuracy (0.9%rdg + 5dgt)
600.0 V Resolution 0.1 V; Accuracy (0.9%rdg + 5dgt)
1000 V Resolution 1 V; Accuracy (1.2%rdg + 5dgt)
AC TRMS Voltage (Input impedance >10 MΩ; Overload protection 1000 V DC/AC rms)
600.0 mV Resolution 0.1 mV; Accuracy (1.0%rdg + 5dgt) [50 Hz–1 kHz], (3.0%rdg + 5dgt) [1 kHz–5 kHz]
6.000 V Resolution 0.001 V; Accuracy (1.0%rdg + 5dgt) [50 Hz–1 kHz], (3.0%rdg + 5dgt) [1 kHz–5 kHz]
60.00 V Resolution 0.01 V; Accuracy (1.0%rdg + 5dgt) [50 Hz–1 kHz], (3.0%rdg + 5dgt) [1 kHz–5 kHz]
600.0 V Resolution 0.1 V; Accuracy (1.0%rdg + 5dgt) [50 Hz–1 kHz], (3.0%rdg + 5dgt) [1 kHz–5 kHz]
1000 V Resolution 1 V; Accuracy (1.0%rdg + 5dgt) [50 Hz–1 kHz], Not specified [1 kHz–5 kHz]
AC Voltage notes Accuracy specified from 5% to 100% of the measuring range and crest factor ≤3. PEAK function accuracy (10%rdg + 30dgt), response time 1 ms. dBV function accuracy (1.5%rdg + 5dgt) (f≤60 Hz), (3.0%rdg + 5dgt) (60 Hz–1 kHz), not specified (1–5 kHz). For non-sinusoidal waveforms: (4.5%rdg + 10dgt) (50 Hz–1 kHz), (10.0%rdg + 10dgt) (1 kHz–5 kHz)
AC+DC TRMS Voltage (50 Hz–1 kHz; Input impedance >10 MΩ; Overload protection 1000 V DC/AC rms)
600.0 mV Resolution 0.1 mV; Accuracy (1.5%rdg + 10dgt)
6.000 V Resolution 0.001 V; Accuracy (1.5%rdg + 10dgt)
60.00 V Resolution 0.01 V; Accuracy (1.5%rdg + 10dgt)
600.0 V Resolution 0.1 V; Accuracy (1.5%rdg + 10dgt)
1000 V Resolution 1 V; Accuracy (1.5%rdg + 10dgt)
DC/AC TRMS Voltage with Low Impedance (LoZ) (Input impedance approx 3 kΩ; Overload protection 1000 V DC/AC rms)
6.000 V Resolution 0.001 V; Accuracy (3.0%rdg + 40dgt)
60.00 V Resolution 0.01 V; Accuracy (3.0%rdg + 40dgt)
600.0 V Resolution 0.1 V; Accuracy (3.0%rdg + 40dgt)
1000 V Resolution 1 V; Accuracy (3.0%rdg + 40dgt)
LoZ note AC+DC accuracy: (3.5%rdg + 40dgt)
Diode Test
Max test current <1.5 mA
Open voltage 2.8 V
4-20 mA % Readings
Range -25% to 125%
Resolution 0.1%
Accuracy 50dgt
Scaling 0 mA = -25%, 4 mA = 0%, 20 mA = 100%, 24 mA = 125%
DC Current (Overload protection: Fast Fuse 0.8 A/1 kVAC/DC on inputs mA, µA; Fast Fuse 10 A/1 kVAC/DC on 10 A input)
600.0 µA Resolution 0.1 µA; Accuracy (1.5%rdg + 5dgt)
6000 µA Resolution 1 µA; Accuracy (1.5%rdg + 5dgt)
60.00 mA Resolution 0.01 mA; Accuracy (1.5%rdg + 5dgt)
600.0 mA Resolution 0.1 mA; Accuracy (1.5%rdg + 5dgt)
10.00 A Resolution 0.01 A; Accuracy (1.5%rdg + 5dgt)
AC TRMS Current (Overload protection: Fast Fuse 0.8 A/1 kVAC/DC on inputs mA, µA; Fast Fuse 10 A/1 kVAC/DC on 10 A input)
600.0 µA Resolution 0.1 µA; Accuracy (2.5%rdg + 5dgt) [50 Hz–1 kHz], (3.5%rdg + 5dgt) [1 kHz–5 kHz]
6000 µA Resolution 1 µA; Accuracy (2.5%rdg + 5dgt) [50 Hz–1 kHz], (3.5%rdg + 5dgt) [1 kHz–5 kHz]
60.00 mA Resolution 0.01 mA; Accuracy (2.5%rdg + 5dgt) [50 Hz–1 kHz], (3.5%rdg + 5dgt) [1 kHz–5 kHz]
600.0 mA Resolution 0.1 mA; Accuracy (2.5%rdg + 5dgt) [50 Hz–1 kHz], (3.5%rdg + 5dgt) [1 kHz–5 kHz]
10.00 A Resolution 0.01 A; Accuracy (2.5%rdg + 5dgt) [50 Hz–1 kHz], (3.5%rdg + 5dgt) [1 kHz–5 kHz]
AC Current notes Accuracy specified from 5% to 100% of the measuring range. PEAK function accuracy (10%rdg + 30dgt). AC+DC accuracy: (2.8%rdg + 5dgt) (50 Hz–1 kHz). For non-sinusoidal waveforms: (4.5%rdg + 10dgt) (50 Hz–1 kHz), (10.0%rdg + 10dgt) (1 kHz–5 kHz)
DC Current with Transducer Clamps (Accuracy referred to instrument only, without transducer clamp; Overload protection 1000 V DC/AC rms)
1000 mA Output ratio 1000 mV/1000 mA; Resolution 1 mA; Accuracy (1.5%rdg + 6dgt)
10 A / 30 A Output ratio 100 mV/1 A; Resolution 0.01 A
40 A Output ratio 10 mV/1 A; Accuracy (1.5%rdg + 26dgt)
100 A Resolution 0.1 A; Accuracy (1.5%rdg + 6dgt)
300 A / 400 A Output ratio 1 mV/1 A; Resolution 1 A; Accuracy (1.5%rdg + 26dgt)
1000 A Accuracy (1.5%rdg + 6dgt)
AC TRMS Current with Transducer Clamps (Accuracy referred to instrument only, without transducer clamp; Overload protection 1000 V DC/AC rms)
1000 mA Output ratio 1000 mV/1000 mA; Resolution 1 mA; Accuracy (2.5%rdg + 10dgt)
10 A / 30 A Output ratio 100 mV/1 A; Resolution 0.01 A
40 A Output ratio 10 mV/1 A; Accuracy (3.5%rdg + 30dgt)
100 A Resolution 0.1 A; Accuracy (2.5%rdg + 10dgt)
300 A / 400 A Output ratio 1 mV/1 A; Resolution 1 A; Accuracy (3.5%rdg + 30dgt)
1000 A Accuracy (2.5%rdg + 10dgt)
3000 A Output ratio 1 mV/1 A; Resolution 1 A
AC Clamp notes Accuracy specified from 5% to 100% of the measuring range. For pulse waveforms: (10.0%rdg + 10dgt). PEAK function accuracy (10%rdg + 30dgt). AC+DC TRMS current accuracy (50 Hz–1 kHz): (3.0%rdg + 10dgt). For non-sinusoidal waveforms: (4.5%rdg + 10dgt) (50 Hz–1 kHz)
Resistance and Continuity Test (Overload protection 1000 V DC/AC rms)
600.0 Ω Resolution 0.1 Ω; Accuracy (2.0%rdg + 9dgt); Buzzer <35 Ω
6.000 kΩ Resolution 0.001 kΩ; Accuracy (1.2%rdg + 5dgt)
60.00 kΩ Resolution 0.01 kΩ; Accuracy (1.2%rdg + 5dgt)
600.0 kΩ Resolution 0.1 kΩ; Accuracy (1.2%rdg + 5dgt)
6.000 MΩ Resolution 0.001 MΩ; Accuracy (2.0%rdg + 10dgt)
60.00 MΩ Resolution 0.01 MΩ; Accuracy (2.0%rdg + 10dgt)
Frequency (Electrical circuits) (Overload protection 1000 V DC/AC rms)
40.00 Hz – 10.00 kHz Resolution 0.01 Hz; Accuracy (0.5%rdg); Sensitivity 15 Vrms
Frequency (Electronic circuits) (Sensitivity >2.0 Vrms min for <100 kHz, 5 Vrms min for >100 kHz, 20% < duty < 80%; Overload protection 1000 V DC/AC rms)
60.000 Hz Resolution 0.001 Hz; Accuracy (1.0%rdg + 2dgt)
600.00 Hz Resolution 0.01 Hz; Accuracy (1.0%rdg + 2dgt)
6.0000 kHz Resolution 0.0001 kHz; Accuracy (1.0%rdg + 2dgt)
60.000 kHz Resolution 0.001 kHz; Accuracy (1.0%rdg + 2dgt)
600.00 kHz Resolution 0.01 kHz; Accuracy (1.0%rdg + 2dgt)
6.0000 MHz Resolution 0.0001 MHz; Accuracy (1.0%rdg + 2dgt)
10.000 MHz Resolution 0.001 MHz; Accuracy (1.0%rdg + 2dgt)
Duty Cycle (Overload protection 1000 V DC/AC rms)
0.1 – 99.9% Resolution 0.01%; Accuracy (1.2%rdg + 2dgt); Pulse width 100 µs – 100 ms; Frequency 5 Hz – 100 kHz
Capacitance (Overload protection 1000 V DC/AC rms)
60.00 nF Resolution 0.01 nF; Accuracy (3.5%rdg + 10dgt)
600.0 nF Resolution 0.1 nF; Accuracy (3.5%rdg + 10dgt)
6.000 µF Resolution 0.001 µF; Accuracy (2.5%rdg + 10dgt)
60.00 µF Resolution 0.01 µF; Accuracy (2.5%rdg + 10dgt)
600.0 µF Resolution 0.1 µF; Accuracy (2.5%rdg + 10dgt)
6.000 mF Resolution 0.001 mF; Accuracy (3.5%rdg + 10dgt)
Temperature with Type K Probe (Accuracy referred to instrument without probe; Overload protection 1000 V DC/AC rms)
-40.0 °C ÷ 600.0 °C Resolution 0.1 °C; Accuracy (2.0%rdg + 3°C)
600 °C ÷ 760 °C Resolution 1 °C; Accuracy (2.0%rdg + 3°C)
-58.0 °F ÷ 600.0 °F Resolution 0.1 °F; Accuracy (2.0%rdg + 5.5°F)
600 °F ÷ 1400 °F Resolution 1 °F; Accuracy (2.0%rdg + 5.5°F)
General Specifications
Display LCD, 3½ dgt (6000 counts) and 4½ dgt (60000 counts), decimal point and bargraph
Polarity Automatic polarity indication
Important: Current inputs are protected by fast fuses rated 0.8 A/1kV AC/DC (mA and µA inputs) and 10 A/1kV AC/DC (10 A input).

About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

HT Italia HT63 CAT IV 60000-Count TRMS Multimeter

Item no : 8090195648
sold recently : Login >>
US$ 4935.50
Pay in 4 interest-free payments of $1233.88 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 22 - Jun 27

Enjoy 20% off shipping

US$ 4935.50

1-11

US$ 4441.95

12-35

US$ 3454.85

36-59

US$ 2961.30

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches